3.3
Bioreactor Setup
for De-epithelialization
1. Put on gloves, remove everything from the BSC, and disinfect
it with 70% ethanol.
2. Disinfect tools, DMEM + Antibiotics, detergents, deionized
filtered H2O, PBS, and other materials one by one (see Note 6).
3.3.1
Detergent
Circuitries
1. Label the Erlenmeyer flasks with a marker, and fill each flask
with the respective solution (a, b, c, or d) using one plastic
pipette per flask as follows:
(a)
Add 250 mL of H2O to the 250 mL flask.
(b)
Add 140 mL of Triton X-100 to a 125 mL flask.
(c)
Add 140 mL of PBS to a 125 mL flask.
(d)
Add 75 mL of SDS to a 125 mL flask.
2. Insert two tubing into each rubber stopper as follows (see
Note 7):
(a)
H2O flask: Place one 5 cm tubing in one stopper hole, and
one 25 cm tubing in the other hole down to the bottom of
the flask.
(b)
Triton X-100 flask: Place one 5 cm tubing in one stopper
hole, and one 15 cm tubing in the other hole down to the
bottom of the flask.
(c)
PBS flask: Place one 5 cm tubing in one stopper hole, and
one 15 cm tubing in the other hole down to the bottom of
the flask.
(d)
SDS flask: Place two 25 cm tubing in each stopper hole,
both down to the bottom of the flask.
3. Introduce each stopper into the corresponding flask.
4. Attach one Tee connector to each of the following: H2O short
tubing, both Triton X-100 tubing, and PBS long tubing
(Fig. 2).
5. Attach one elbow connector to each of the following: H2O
long tubing, PBS short tubing, and both SDS tubing.
6. Connect both H2O and Triton X-100 flask short tubing using
a 15 cm tubing.
7. Connect the Triton X-100 and PBS flask short tubing using a
15 cm tubing.
8. Connect both H2O and Triton X-100 flask long tubing using a
15 cm tubing.
9. Connect the Triton X-100 and PBS flask long tubing using a
15 cm tubing.
10. Attach a 15 cm tubing to H2O short tubing tee connector.
Then, connect it to a one-way valve (flow direction towards the
H2O flask).
De-Epithelialization of Tracheal Grafts
173